Difference between revisions of "Supermarket refrigeration system"

From mintOC
Jump to: navigation, search
(Source Code)
(Optimica)
Line 327: Line 327:
 
     der(x7)=((UA_goods*(x5-x7)+Q_airload-UA_air*(x7-x6))/(M_air*Cp_air))*tf;
 
     der(x7)=((UA_goods*(x5-x7)+Q_airload-UA_air*(x7-x6))/(M_air*Cp_air))*tf;
 
     der(x8)=(((M_ref-x8)/t_fill)*u1-((UA_wall/(M_ref*((0.0217*x0*x0-0.1704*x0+2.2988)*10^5)))*x8*(x6-(-4.3544*x0*x0+29.224*x0-51.2005)))*(1-u1))*tf;
 
     der(x8)=(((M_ref-x8)/t_fill)*u1-((UA_wall/(M_ref*((0.0217*x0*x0-0.1704*x0+2.2988)*10^5)))*x8*(x6-(-4.3544*x0*x0+29.224*x0-51.2005)))*(1-u1))*tf;
//    der(cost) = ((-1.0/((1.0/*time*/)))*cost+(1.0/((1.0/*time*/)))*((u2)*0.5*eta_vol*V_sl*((0.0265*x0*x0*x0-0.4346*x0*x0+2.4923*x0+1.2189)*10^5)))*tf;
+
    der(cost) = ((-1.0/((1/*time*/)))*cost+(1.0/((1/*time*/)))*((u2)*0.5*eta_vol*V_sl*((0.0265*x0*x0*x0-0.4346*x0*x0+2.4923*x0+1.2189)*10^5)))*tf;
    der(cost) = 1.0 / 650 * (((u2)*0.5*eta_vol*V_sl*((0.0265*x0*x0*x0-0.4346*x0*x0+2.4923*x0+1.2189)*10^5)))*tf;
+
  // der(cost) = 1.0 / 650 * (((u2)*0.5*eta_vol*V_sl*((0.0265*x0*x0*x0-0.4346*x0*x0+2.4923*x0+1.2189)*10^5)))*tf;
  
 
   constraint
 
   constraint

Revision as of 15:35, 11 August 2009

Supermarket refrigeration system
State dimension: 1
Differential states: 9
Discrete control functions: 4
Interior point equalities: 9


The supermarket refrigeration system problem is based on a model describing a refrigeration system with 2 parallel connected compressors (called a compressor rack) which only can be controlled stepwise (each single compressor can be turned on or off) and 2 open refrigerated display cases containing goods needed to be refrigerated. Each display case is connected to the refrigeration circuit through an expansion valve which also can only be closed or opened. This valve controls the flow of refrigerant into the evaporator, where it absorbs heat from the surrounding air. The refrigerated air then creates the well-known air-curtain at the front of the display case.

The air temperatures surrounding the goods in each display case are modeled by one differential state each. These states have to be bounded, so that the goods are properly refrigerated.

The model was published by Larsen et. al. in 2007 <bibref>Larsen2007</bibref>. The main goal is to control the refirgeration system energy-optimal. The problem was set up as a benchmark problem for MIOCPs.

The mathematical equations form an ODE model. The initial values of the differential states are not fixed but periodicity of the whole process is required.

The optimal integer control function shows chattering behavior, making the supermarket refrigeration system problem a candidate for benchmarking of algorithms.

Mathematical formulation

For t \in [t_0, t_f] almost everywhere the mixed-integer optimal control problem is given by


\min_{x,u} \frac {1}{t_f - t_0}\int_{t_0}^{t_f} \left( (u_2)\cdot 0.5 \cdot \eta_{vol} \cdot V_{sl} \cdot f \right) dt


\begin{array}{llcl}
 \displaystyle 
 \mbox{s.t.} & 
\dot{x_0}(t) &=&  \dfrac{1}{V_{suc} \cdot \frac{d\rho_{suc}}{dP_{suc}}(x_0)} \cdot \bigg[ 
                    \left(\dfrac{UA_{wall-ref, max}}{M_{ref, max} \cdot
                    \Delta h_{lg}(x_0)}\right) \Big( x_4 \big( x_2 - T_e(x_0) \big)\\ 
&           &&  + \, x_8 \big( x_6 - T_e(x_0) \big) \Big) + \, M_{ref,const}   - \eta_{vol} \cdot V_{sl} \cdot 0.5 \, \left(u_2\right) \rho_{suc}(x_0) 
                \bigg] \\
 &\dot{x_1}(t) &=&  - \dfrac{
                    UA_{goods-air} \left( x_1 - x_3 \right)
}{
                    M_{goods} \cdot C_{p,goods} 
} \\ 
 &\dot{x_2}(t) &=&  \dfrac{
                    UA_{air-wall} \left( x_3-x_2 \right)
                    - \dfrac{UA_{wall-ref,max}}{M_{ref,max}}
                    \, x_4 \big( x_2 - T_e(x_0) \big)
}{
                    M_{wall} \cdot C_{p,wall}
} \\ [2.5ex]
&\dot{x_3}(t) &=&  \dfrac{
                    UA_{goods-air} \left( x_1-x_3 \right) + \dot{Q}_{airload}
                     - UA_{air-wall} \, (x_3-x_2)
}{
                    M_{air} \cdot C_{p,air}
} \\ [2.5ex]
&\dot{x_4}(t) &=&   \left(\dfrac{M_{ref,max} - x_4}{\tau_{fill}} \right) u_0
                    - \left( \dfrac{UA_{wall-ref,max}}{M_{ref,max} \cdot \Delta h_{lg}(x_0)} \,
                    x_4 \big( x_2 - T_e(x_0) \big) \right) (1-u_0)
                 \\ \\
&\dot{x_5}(t) &=&  - \dfrac{
                    UA_{goods-air} \left( x_5 - x_7 \right)
}{
                    M_{goods} \cdot C_{p,goods} 
} \\ 
 &\dot{x_6}(t) &=&  \dfrac{
                    UA_{air-wall} \left( x_7-x_6 \right)
                    - \dfrac{UA_{wall-ref,max}}{M_{ref,max}}
                    \, x_8 \big( x_6 - T_e(x_0) \big)
}{
                    M_{wall} \cdot C_{p,wall}
} \\ [2.5ex]
&\dot{x_7}(t) &=&  \dfrac{
                    UA_{goods-air} \left( x_5-x_7 \right) + \dot{Q}_{airload}
                     - UA_{air-wall} \, (x_7-x_6)
}{
                    M_{air} \cdot C_{p,air}
} \\ [2.5ex]
&\dot{x_8}(t) &=&   \left(\dfrac{M_{ref,max} - x_8}{\tau_{fill}} \right) u_1
                    - \left( \dfrac{UA_{wall-ref,max}}{M_{ref,max} \cdot \Delta h_{lg}(x_0)} \,
                    x_8 \big( x_6 - T_e(x_0) \big) \right) (1-u_1)
                 \\ [4ex]

 & x_3(t) &\geq& 2.0 \quad \forall t \in [t_0, t_f],\\
 & x_3(t) &\leq& 5.0 \quad \forall t \in [t_0, t_f],\\
 & x_7(t) &\geq& 2.0 \quad \forall t \in [t_0, t_f],\\
 & x_7(t) &\leq& 5.0 \quad \forall t \in [t_0, t_f],\\
 & x_0(t) &\leq& 1.7 \quad \forall t \in [t_0, t_f], \\
 & x_i(t_0) &=& free \quad \forall i \in \{0,\dots, 8\}, \\
 & x_i(t_f) &=& x_i(t_0) \quad \forall i \in \{0,\dots, 8\}, \\
 & u_i(t)   &\in&  \{0, 1\} \quad \forall i \in \{0,\dots, 2\}, \\
 & t_f    &\in& [ 650, 750 ]. 

\end{array}


Here the differential state x_0 describes the suction pressure in the suction manifold (in bar). The next three states model temperatures in the first display case (in °C). x_1 is the goods' temperature, x_2 the one of the evaporator wall and x_3 the air temperature surrounding the goods. x_4 then models the mass of the liquefied refrigerant in the evaporator (in kg).

(x_5, x_6, x_7, x_8) describe the corresponding states in the second display case.

u_0 describes the inlet valve of the first display case, u_1 respectively the valve of the second display case. u_2, u_3 denote the activity of a single compressor.

The following polynomial functions are used in the model description originating from interpolations:


\begin{array}{rcl}

T_e(x_0)                             &=& -4.3544 x_0^2 + 29.224 x_0 - 51.2005,\\
\Delta h_{lg}(x_0)                   &=& (0.0217 x_0^2 - 0.1704 x_0 + 2.2988)\cdot 10^5, \\
\rho_{suc}(x_0)                      &=& 4.6073 x_0 + 0.3798, \\
\frac{d\rho_{suc}}{dP_{suc}}(x_0)    &=& -0.0329 {x_0}^3 + 0.2161 {x_0}^2 - 0.4742 x_0 + 5.4817,\\
f(x_0)                               &=& (0.0265 x_0^3 - 0.4346 x_0^2 + 2.4923 x_0 + 1.2189) \cdot 10^5.
\end{array}

Parameters

These fixed values are used within the model for the day scenario. A night scenario is also available, see Variants.

Symbol Value Unit Description
\dot{Q}_{airload} 3000.00 \frac{J}{s} Disturbance, heat transfer from outside the display case
\dot{m}_{ref,const} 0.20 \frac{kg}{s} Disturbance, constant mass flow of refrigerant

from unmodeled entities

M_{goods} 200.00 kg Mass of goods
C_{p,goods} 1000.00 \frac{J}{kg \cdot K} Heat capacity of goods

UA_{goods-air} 300.00 \frac{J}{s \cdot K} Heat transfer coefficient between goods

and air

M_{wall} 260.00 kg Mass of evaporator wall
C_{p,wall} 385.00 \frac{J}{kg \cdot K} Heat capacity of evaporator wall
UA_{air-wall} 500.00 \frac{J}{s \cdot K} Heat transfer coefficient between air and

wall

M_{air} 50.00 kg Mass of air in display case
C_{p,air} 1000.00 \frac{J}{kg \cdot K} Heat capacity of air
UA_{wall-ref,max} 4000.00 \frac{J}{s \cdot K} Maximum heat transfer coefficient between

refrigerant and evaporator wall

\tau_{fill} 40.00 s Parameter describing the filling time of the

evaporator under opened valve

T_{SH} 10.00 K Superheat in the suction manifold
M_{ref,max} 1.00 kg Maximum mass of refrigerant in evaporator
V_{suc} 5.00 m^3 Total volume of suction manifold
V_{sl} 0.08 \frac{m^3}{s} Total displacement volume
\eta_{vol} 0.81 - Volumetric efficiency

Reference Solutions

For the relaxed problem (we only demand u_i(t) \in  [0,1] instead of u_i(t) \in  \{0,1\} the optimal solution is 12072.45. If we restrict ourselves to a solution with only integer controls we obtain the optimum objective value 12252.81.

Source Code

C

The differential equations in C code:

// number of compressors
#define NVALVES 2
 
// constants
#define M_GOODS 200.0
#define C_P_GOODS 1000.0
#define UA_GOODS_AIR 300.0
#define M_WALL 260.0
#define C_P_WALL 385.0
#define UA_AIR_WALL 500.0
#define M_AIR 50.0
#define C_P_AIR 1000.0
#define UA_WALL_REF_MAX 4000.0
#define M_REF_MAX 1.0
#define TAU_FILL 40.0
#define T_SH 10.0
#define V_SUC 5.0
#define V_SL 0.08 // 2 display cases - 2 compressors
// #define V_SL 0.095 // 3 display cases - 3 compressors
#define ETA_VOL 0.81
 
// disturbances - day scenario
#define Q_AIRLOAD 3000.0
#define M_REF_CONST 0.2
 
// disturbances - night scenario
// #define Q_AIRLOAD 1800.0
// #define M_REF_CONST 0.0
 
double delta_h = (0.0217*xd[0]*xd[0] - 0.1704*xd[0] + 2.2988)*1e5;
double T_e = -4.3544*xd[0]*xd[0] + 29.224*xd[0] - 51.2005;
double rho_suc = 4.6073*xd[0] + 0.3798;
double rho_suc__P_suc = -0.0329*xd[0]*xd[0]*xd[0] + 0.2161*xd[0]*xd[0] - 0.4742*xd[0] + 5.4817;
double f = (0.0265*xd[0]*xd[0]*xd[0] -0.4346*xd[0]*xd[0] + 2.4923*xd[0] + 1.2189)*1e5;
 
double Q_goods_air[NVALVES];
double Q_air_wall[NVALVES];
double UA_wall_ref[NVALVES];
double Q_e[NVALVES];
double m[NVALVES];
 
double m_in_suc = 0.0;
 
int i;
 
for (i=0; i<NVALVES; i++){
    Q_goods_air[i] = UA_GOODS_AIR*(xd[1 + i*4] - xd[3 + i*4]);
    Q_air_wall[i] = UA_AIR_WALL*(xd[3 + i*4] - xd[2 + i*4]);
    UA_wall_ref[i] = UA_WALL_REF_MAX * xd[4 + 4*i]/M_REF_MAX;
    Q_e[i] = UA_wall_ref[i]*(xd[2 + 4*i] - T_e);
 
    m[i] = Q_e[i]/delta_h;
    m_in_suc += m[i];
}
 
double V_comp = 0.0;
double comp_scale = (double) 1.0/NCOMPS;
V_comp = comp_scale*u[NVALVES]*ETA_VOL*V_SL;
 
 
 
// suction pressure
rhs[0] = (m_in_suc + M_REF_CONST - V_comp*rho_suc) / (V_SUC*rho_suc__P_suc);
 
// for each display/valve
for (i=0; i<NVALVES; i++){
 
    // temperatures:
 
    // goods
    rhs[1 + i*4] = - Q_goods_air[i]/(M_GOODS*C_P_GOODS);
 
    // wall
    rhs[2 + i*4] = (Q_air_wall[i] - Q_e[i])/(M_WALL*C_P_WALL);
 
    // air
    rhs[3 + i*4] = ((Q_goods_air[i] + Q_AIRLOAD - Q_air_wall[i]) /(M_AIR*C_P_AIR));
 
    // mass of liquefied refrigerant:
    rhs[4 + i*4] = ((M_REF_MAX - xd[4 + 4*i])/TAU_FILL * u[i] - m[i] * (1 - u[i]));
}

Optimica

package Supermarket_pack
 
  optimization Supermarket_Opt (objective = cost(tf),
                         startTime = 0,
                         finalTime=1)
 
    // Parameters
    parameter Real Q_airload = 3000.00;             
    parameter Real m_ref = 0.20;             
    parameter Real M_goods=200.00;
    parameter Real Cp_goods=1000.00;
    parameter Real UA_goods=300.00;
    parameter Real M_wall=260.00;
    parameter Real Cp_wall=385.00;
    parameter Real UA_air=500.00;
    parameter Real M_air=50.00;
    parameter Real Cp_air=1000.00;
    parameter Real UA_wall=4000.00;
    parameter Real t_fill=40.00;
    parameter Real T_sh=10.00;
    parameter Real M_ref=1.00;
    parameter Real V_suc=5.00;
    parameter Real V_sl=0.08;             
    parameter Real eta_vol=0.81;
    parameter Real tf(free=true,min=650,max=750)=650;
 
   // The states
    Real x0;
    Real x1;
    Real x2;
    Real x3;
    Real x4;
    Real x5;
    Real x6;
    Real x7;
    Real x8;
    Real cost(start=0);
 
    // The control signal
    input Real u0(free=true,min=0,max=1);
    input Real u1(free=true,min=0,max=1);
    input Real u2(free=true,min=0,max=1);
 
//Te=(-4.3544*x0*x0+29.224*x0-51.2005)
//delta_h=((0.0217*x0*x0-0.1704*x0+2.2988)*10^5)
//rho_suc=(4.6073*x0+0.3798)
//drho=(-0.0329*x0*x0*x0+0.2161*x0*x0-0.4742*x0+5.4817)
//f=((0.0265*x0*x0*x0-0.4346*x0*x0+2.4923*x0+1.2189)*10^5)
 
  equation
    der(x0) = ((1.0/(V_suc*(-0.0329*x0*x0*x0+0.2161*x0*x0-0.4742*x0+5.4817)))*((UA_wall/(M_ref*((0.0217*x0*x0-0.1704*x0+2.2988)*10^5)))*(x4*(x2-(-4.3544*x0*x0+29.224*x0-51.2005))+x8*(x6-(-4.3544*x0*x0+29.224*x0-51.2005)))+M_ref-eta_vol*V_sl*0.5*(u2)*(4.6073*x0+0.3798)))*tf;
    der(x1) =(-UA_goods*(x1-x3)/M_goods*Cp_goods)*tf;
    der(x2)=((UA_air*(x3-x2)-(UA_wall/M_ref)*x4*(x2-(-4.3544*x0*x0+29.224*x0-51.2005)))/(M_wall*Cp_wall))*tf;
    der(x3)=((UA_goods*(x1-x3)+Q_airload-UA_air*(x3-x2))/(M_air*Cp_air))*tf;
    der(x4)=(((M_ref-x4)/t_fill)*u0-((UA_wall/(M_ref*((0.0217*x0*x0-0.1704*x0+2.2988)*10^5)))*x4*(x2-(-4.3544*x0*x0+29.224*x0-51.2005)))*(1-u0))*tf;
    der(x5)=(-UA_goods*(x5-x7)/(M_goods*Cp_goods))*tf;
    der(x6)=((UA_air*(x7-x6)-(UA_wall/M_ref)*x8*(x6-(-4.3544*x0*x0+29.224*x0-51.2005)))/(M_wall*Cp_wall))*tf;
    der(x7)=((UA_goods*(x5-x7)+Q_airload-UA_air*(x7-x6))/(M_air*Cp_air))*tf;
    der(x8)=(((M_ref-x8)/t_fill)*u1-((UA_wall/(M_ref*((0.0217*x0*x0-0.1704*x0+2.2988)*10^5)))*x8*(x6-(-4.3544*x0*x0+29.224*x0-51.2005)))*(1-u1))*tf;
    der(cost) = ((-1.0/((1/*time*/)))*cost+(1.0/((1/*time*/)))*((u2)*0.5*eta_vol*V_sl*((0.0265*x0*x0*x0-0.4346*x0*x0+2.4923*x0+1.2189)*10^5)))*tf;
   // der(cost) = 1.0 / 650 * (((u2)*0.5*eta_vol*V_sl*((0.0265*x0*x0*x0-0.4346*x0*x0+2.4923*x0+1.2189)*10^5)))*tf;
 
  constraint
    x3>=2.0;
    x3<=5.0;
    x7>=2.0;
    x7<=5.0;
    x0<=1.7;
    x0(tf)=x0(startTime);
    x1(tf)=x1(startTime);
    x2(tf)=x2(startTime);
    x3(tf)=x3(startTime);
    x4(tf)=x4(startTime);
    x5(tf)=x5(startTime);
    x6(tf)=x6(startTime);
    x7(tf)=x7(startTime);
    x8(tf)=x8(startTime);
 
  end Supermarket_Opt;
 
end Supermarket_pack;

Variants

Since the compressors are parallel connected one can introduce a single control  u_2 \in \{0,1,2\} instead of two equivalent controls. The same holds for scenarions with  n parallel connected compressors.

In the paper <bibref>Larsen2007</bibref> mentioned above, the problem was stated slightly different:

  • The temperature constraints weren't hard bounds but there was a penalization term added to the objective function to minimize the violation of these constraints.
  • The differential equation for the mass of the refrigerant had another switch, if the valve (e.g. u_0) is closed. It was formulated this way:


\dot{x_4} =  \begin{cases}

\dfrac{M_{ref,max} - x_4}{\tau_{fill}} & \qquad \text{if} \quad u_0 = 1 \\ \\
- \dfrac{UA_{wall-ref,max}}{M_{ref,max} \cdot \Delta h_{lg}(x_0)} x_4 \big( x_2 - T_e(x_0) \big) & \qquad \text{if} \quad u_0 = 0 \quad \text{and}\quad  x_4 > 0 \\ \\ 
0 & \qquad \text{if} \quad u_0 = 0 \quad \text{and} \quad x_4 = 0

\end{cases}

This additional switch is redundant because the mass itself is a factor on the right hand side and so the complete right hand side is 0 if x_4 = 0.

  • A night scenario with two different parameters was given. At night the following parameters change their value:


\begin{array}{lcrr}
\dot{Q}_{airload}   &=& 1800.00 & \frac{J}{s}, \\
\dot{m}_{ref,const} &=&    0.00 & \frac{kg}{s},  \\
\end{array}

Additionally the constraint on the suction pressure x_0(t) is softened to x_0(t) \leq 1.9.

  • No periodicity was required but the solution on a fixed time horizon 4 hours - 2 in day scenario and 2 in night scenario - with t_f = 14400 was asked.
  • The number of compressors and display cases is not fixed. Larsen also proposed the problem with 3 compressors and 3 display cases. This leads to a change in the compressor rack's preformance to V_{sl} = 0.095 \frac{m^3}{s}. Unfortunately this constant is only given for these two cases although Larsen proposed scenarios with more compressors and display cases.

References